Datos Rápidos modelos serie NPE-A2
43.9cm an x 69.6cm al x 33.5cm prof (17.3" an x 27.4" al x 13.2" prof)
FT Williams and Associates Limited
835 Captain Eiley Street
Belize City, Belize
Oficina: +501 223 6065
Oficina: +501 223 6066
Contacto: Keith Mira
Correo: ftwilliams@btl.net
Sitio Web: www.ftwilliams.bz
Temp Rise | NPE-240A2 |
19.4 °C (35 °F) | 42.4 l/m (11.2 GPM) |
22.2 °C (40 °F) | 37.1 l/m (9.8 GPM) |
25 °C (45 °F) | 32.9 l/m (8.7 GPM) |
27.8 °C (50 °F) | 29.5 l/m (7.8 GPM) |
30.6 °C (55 °F) | 26.9 l/m (7.1 GPM) |
33.3 °C (60 °F) | 24.6 l/m (6.5 GPM) |
36.1 °C (65 °F) | 22.7 l/m (6 GPM) |
38.9 °C (70 °F) | 21.2 l/m (5.6 GPM) |
41.7 °C (75 °F) | 19.7 l/m (5.2 GPM) |
44.4 °C (80 °F) | 18.5 l/m (4.9 GPM) |
47.2 °C (85 °F) | 17.4 l/m (4.6 GPM) |
50 °C (90 °F) | 16.7 l/m (4.4 GPM) |
55.6 °C (100 °F) | 14.8 l/m (3.9 GPM) |
61.1 °C (110 °F) | 13.6 l/m (3.6 GPM) |
66.7 °C (120 °F) | 12.5 l/m (3.3 GPM) |
72.2 °C (130 °F) | 11.4 l/m (3 GPM) |
77.8 °C (140 °F) | 10.6 l/m (2.8 GPM) |
Modelo | NPE-240A2 |
---|---|
Gas natural | 3.9 - 58.57 kWh (13,300 - 199,900 BTU/h) |
Propano | 3.9 - 58.57 kWh (13,300 - 199,900 BTU/h) |
Navien sin tanque | 179.0 thm $195* |
---|---|
Otros sin tanque | 228 thm $249 |
Tanque de 189 litros | 293 thm $319 |
Reduzca el índice domiciliario HERS
Puntos LEED de Green Building Council de EE.UU.
Calentador de agua | 1 Punto |
---|---|
Ubicación | 2 Puntos |
Recirculación | 3 Puntos |
Modelo | NPE-240A2 | |
---|---|---|
Capacidad térmica (entrada) | Gas natural | 3.9 - 58.57 kWh (13,300 - 199,900 BTU/h) |
Propano | 3.9 - 58.57 kWh (13,300 - 199,900 BTU/h) | |
Eficiencia Térmica | Clasificaciones de eficiencia de GN y LP (UEF) | Hasta 100% (ANCE - NOM) |
Caudal (agua caliente doméstica - sanitaria) | Alza de temp. de 19°C | 42.4 l/m (11.2 GPM) |
Alza de temp. de 25°C | 32.9 l/m (8.7 GPM) | |
Alza de temp. de 37°C | 21.2 l/m (5.6 GPM) | |
Dimensiones | 43.9cm an x 69.6cm al x 33.5cm prof (17.3" an x 27.4" al x 13.2" prof) | |
Peso de boiler | 34.9 kg (77 lbs) | |
Installation location | Instalado en pared interior o exterior | |
Ventilación | Ventilación directa de tiro forzado | |
Encendido | Encendido electrónico | |
Presión de agua | 1.05-10.55 kg/cm2 (15-150 PSI) | |
Presión de suministro de gas natural (desde la fuente) | 0.87 kPa a 2.61 kPa (3.5 " WC a 10.5 " WC) | |
Presión de suministro de gas propano (desde la fuente) | 1.99 kPa a 3.23 kPa (8 " WC a 13 " WC) | |
Presión del colector de gas natural (mín.-máx.) | -0.0075 kPa a -0.24 kPa (-0.03 " WC a -0.96 " WC) | |
Presión del colector de gas propano (mín.-máx.) | -0.005 kPa a -0.24 kPa (-0.02 " WC a -0.96 " WC) | |
Caudal mínimo | 1.89 l/m (0.5 GPM), < 0.04 l/m (0.01 GPM) option* | |
Tamaños de conexión | Entrada de agua fría | 3/4" |
Salida de agua caliente | 3/4" | |
Entrada de gas | 3/4" | |
Suministro | Main supply | 120V AC, 60 Hz |
Consumo máximo de energía | 200 W (máx. 2 A), 350 W (máx. 4 A) con bomba externa conectada | |
Materiales | Revestimiento | Acero al carbono laminado en frío |
Intercambiadores de calor | Intercambiadores de calor primarios: acero inoxidable, intercambiadores secundarios: acero inoxidable | |
Ventilación | Escape | PVC de 2" o 3", CPVC, polipropileno / ventilación de gas especial de 2" o 3" tipo BH (clase II, A/B/C) |
Admisión | PVC de 2" o 3", CPVC, polipropileno / ventilación de gas especial de 2" o 3" tipo BH (clase II, A/B/C) | |
Espacio libre para ventilación | 0" para combustibles | |
Altas elevaciones | 10,100 feet for both NG or LP gas. Please refer to Installation Manual for additional details and instructions. | |
Dispositivos de seguridad | Control de llama con barra, APS, detector de operación de encendido, interruptor y de sensor limitado temperatura de agua alta, fusible para sobrecarga de energía |